10 Rules for Designing Vapor Barriers Houston TX

Building envelope and moisture control specialists Richard Keleher and Judd Peterson provide 10 important rules for designing effective vapor barrier systems.

Local Companies

Element Architects
713-874-0775
1210 West Clay #6
Houston, TX
America P E Bros Corp
(281) 970-9425
9315 Turtle Log Trl
Houston, TX
Rather Roy L Engr
(713) 622-1492
3452 Piping Rock Ln
Houston, TX
Camp Dresser & McKee Inc
(713) 552-1340
3050 Post Oak Blvd
Houston, TX
Erin Engineering
(281) 477-3419
17350 State Highway 249
Houston, TX
Bergaila & Assoc Inc
(281) 496-0803
1880 S Dairy Ashford St
Houston, TX
Power Engineers Inc Engnr
(281) 765-5500
15621 Blue Ash Dr
Houston, TX
Tetra Tech Inc
(832) 251-5160
2901 Wilcrest Dr Ste 405
Houston, TX
Bechtel Corp
(713) 235-2000
3000 Post Oak Msc Blvd # 70
Houston, TX
Camp Dresser & McKee Inc
(713) 423-7300
3050 Post Oak Blvd
Houston, TX

provided by: Building Design and Construction

Improper use of vapor barriers is one of the leading causes of moisture-related issues in buildings today.

Vapor barriers, or vapor retarders, are designed to prevent wall assemblies from getting wet. But when these systems are not designed and installed properly, they can actually prevent assemblies from drying, which can lead to unwanted moisture intrusion.

"Diffusion can be a problem, especially when vapor retarders are used inappropriately-for example, when vinyl wall covering is used in the Southeast," says Richard Keleher, AIA, CSI, LEED, senior architect at Richard Keleher Architect, Concord, Mass.

Keleher says the function of a vapor barrier is to retard the migration of water vapor. Specifying a vapor barrier's permeability and its proper location within the assembly are a function of climate, interior conditions, and the characteristics of the materials that comprise the assembly.

"Condensation occurs when water vapor in the air meets a surface that is below the dewpoint," says Keleher. "This tends to happen at thermal bridges in uninsulated or poorly insulated assemblies, and when the interior humidity is unusually high."

To help AEC professionals get vapor barriers right, Keleher and fellow building envelope expert Judd Peterson, AIA, president of Judd/Allen Group, Edina, Minn., offer these tips:

1 The fundamentals of creating a proper vapor barrier include developing the thermal section of exterior wall or roof; determining the dewpoint for the interior environment, locating the dewpoint in the wall construction; verifying the vapor barrier location and the thermal performance of the insulation relative to the dewpoint location. For relative temperature, humidity, and dewpoint readings, you need to refer to the psychometric chart.

2 Vapor barriers come in several varieties. They include:

Class I vapor retarder - 0.1 perm or less

Class II vapor retarder - 1.0 perm or less and greater than 0.1 perm

Class III vapor retarder - 10 perm or less and greater than 1.0 perm

(Per Canadian General Standards Board)

Vapor impermeable - 0.1 perm or less

Vapor semi-impermeable-1.0permorless and greater than 0.1perm

Vapor semi-impermeable-10permorless and greaterthan1.0perm

Vapor permeable - Greater than 10 perms

(Per ASHRAE)

3 In climates with extreme cold temperature, make sure to provide a true, impermeable vapor barrier that is rated 0.10 perm or less on the warm side of the insulation. However, it's important to note that most uncontrolled moisture in exterior walls is conveyed by airflow, not vapor transmission.

4 Check vapor barrier continuity at the interior plane of insulation around the entire building envelope, looking for penetrations, corners, and junctions. Continuously seal all laps and penetrations.

5 Provide under-slab vapor barrier sheets using polyolefin membranes, not polyethylene, and continuously seal all laps and penetrations. Place the vapor barrier directly under the concrete slabs on grade and cover the slabs with wet burlap to reduce the risk of curling during drying and curing.

6 Avoid using vapor barriers where vapor retarders would provide satisfactory performance. Consider stepping down in performance if the physics of the environment allow it; this encourages permeability for evaporation and drying.

7 In general, avoid double vapor barriers where possible and where enclosure vapor barriers cannot be perfected because damaging moisture can accumulate between flawed vapor barriers. However, note that double vapor barriers are common where they can be perfected, such as in curtain wall construction, glazing, and roofing.

8 Consider using SVR (smart vapor retarder) membranes, which are polyamide sheet material that vary their permeability depending on ambient humidity of the adjacent spaces. Also be sure to note restrictions on using SVRs, which exist due to relatively heavy humidity requirements.

8 Consider using spray foam insulation material to provide a vapor barrier in awkward or hard-to-reach locations. For a vapor barrier that also provides a fire/smoke seal, consider using additional spray coatings.

9 Beware of inadvertently creating a vapor barrier finish in a location or plane where one does not belong-vinyl wall covering on an exterior drywall surface, for example.

Richard Keleher, AIA, CSI, LEED, is senior architect at Richard Keleher Architect, Concord, Mass. He can be reached at 978-369-4550 or kel@rkeleher.com.

Judd Peterson, AIA, is president of Judd/Allen Group, Edina, Minn. He can be reached at 952-224-5050 or jpeterson@juddallen.com.



author: Richard Keleher and Judd Peterson

Building Design and Construction. Copyright © 2007 Reed Business Information, a division of Reed Elsevier Inc. All rights reserved.

Featured Local Company

Element Architects

713-874-0775
1210 West Clay #6
Houston, TX

Related Local Events
American Contract Manufacturers Show (AmCon-Houston)
Dates: 11/4/2009 - 11/5/2009
Location: The Reliant Center at Reliant Park, Houston
Houston, TX
View Details

Digital Exploration and Production
Dates: 10/19/2009 - 10/19/2009
Location: The Omni Galleria, Houston
Houston, TX
View Details

ISA EXPO 2009
Dates: 10/6/2009 - 10/8/2009
Location: Reliant Park
Houston, TX
View Details

Texas Home & Garden Show
Dates: 8/21/2009 - 8/23/2009
Location: George R. Brown Convention Center
Houston, TX
View Details