10 Rules for Designing Vapor Barriers Louisville KY

Building envelope and moisture control specialists Richard Keleher and Judd Peterson provide 10 important rules for designing effective vapor barrier systems.

Local Companies

Studio A Architecture
502-589-8007
1371 Bardstown Road
Louisville, KY
TONY WALDRON ARCHITECTS
502-235-4454
228 ALBANY AVENUE
LOUISVILLE, KY
Forza Architecture, Inc.
502.896.1328
654 South Shelby Street
louisville, KY
Plan Ahead, Inc.
502-817-7526
3720 7th Street
Louisville, KY
Design First, Inc.
502.744.8716
11900 plantside Dr
Louisville, KY
Wilson John Doyle Engr
(502) 584-6271
315 W Market St
Louisville, KY
Biagi Chance Cummins London Titzer Inc
(502) 584-0011
601 W Main St
Louisville, KY
Quest Engineers Inc
(502) 584-4118
401 N Main St
Louisville, KY
Strand Associates Inc
(502) 583-7020
325 W Main St
Louisville, KY
Afl Network Services
(502) 561-9030
534 Armory Pl
Louisville, KY

provided by: Building Design and Construction

Improper use of vapor barriers is one of the leading causes of moisture-related issues in buildings today.

Vapor barriers, or vapor retarders, are designed to prevent wall assemblies from getting wet. But when these systems are not designed and installed properly, they can actually prevent assemblies from drying, which can lead to unwanted moisture intrusion.

"Diffusion can be a problem, especially when vapor retarders are used inappropriately-for example, when vinyl wall covering is used in the Southeast," says Richard Keleher, AIA, CSI, LEED, senior architect at Richard Keleher Architect, Concord, Mass.

Keleher says the function of a vapor barrier is to retard the migration of water vapor. Specifying a vapor barrier's permeability and its proper location within the assembly are a function of climate, interior conditions, and the characteristics of the materials that comprise the assembly.

"Condensation occurs when water vapor in the air meets a surface that is below the dewpoint," says Keleher. "This tends to happen at thermal bridges in uninsulated or poorly insulated assemblies, and when the interior humidity is unusually high."

To help AEC professionals get vapor barriers right, Keleher and fellow building envelope expert Judd Peterson, AIA, president of Judd/Allen Group, Edina, Minn., offer these tips:

1 The fundamentals of creating a proper vapor barrier include developing the thermal section of exterior wall or roof; determining the dewpoint for the interior environment, locating the dewpoint in the wall construction; verifying the vapor barrier location and the thermal performance of the insulation relative to the dewpoint location. For relative temperature, humidity, and dewpoint readings, you need to refer to the psychometric chart.

2 Vapor barriers come in several varieties. They include:

Class I vapor retarder - 0.1 perm or less

Class II vapor retarder - 1.0 perm or less and greater than 0.1 perm

Class III vapor retarder - 10 perm or less and greater than 1.0 perm

(Per Canadian General Standards Board)

Vapor impermeable - 0.1 perm or less

Vapor semi-impermeable-1.0permorless and greater than 0.1perm

Vapor semi-impermeable-10permorless and greaterthan1.0perm

Vapor permeable - Greater than 10 perms

(Per ASHRAE)

3 In climates with extreme cold temperature, make sure to provide a true, impermeable vapor barrier that is rated 0.10 perm or less on the warm side of the insulation. However, it's important to note that most uncontrolled moisture in exterior walls is conveyed by airflow, not vapor transmission.

4 Check vapor barrier continuity at the interior plane of insulation around the entire building envelope, looking for penetrations, corners, and junctions. Continuously seal all laps and penetrations.

5 Provide under-slab vapor barrier sheets using polyolefin membranes, not polyethylene, and continuously seal all laps and penetrations. Place the vapor barrier directly under the concrete slabs on grade and cover the slabs with wet burlap to reduce the risk of curling during drying and curing.

6 Avoid using vapor barriers where vapor retarders would provide satisfactory performance. Consider stepping down in performance if the physics of the environment allow it; this encourages permeability for evaporation and drying.

7 In general, avoid double vapor barriers where possible and where enclosure vapor barriers cannot be perfected because damaging moisture can accumulate between flawed vapor barriers. However, note that double vapor barriers are common where they can be perfected, such as in curtain wall construction, glazing, and roofing.

8 Consider using SVR (smart vapor retarder) membranes, which are polyamide sheet material that vary their permeability depending on ambient humidity of the adjacent spaces. Also be sure to note restrictions on using SVRs, which exist due to relatively heavy humidity requirements.

8 Consider using spray foam insulation material to provide a vapor barrier in awkward or hard-to-reach locations. For a vapor barrier that also provides a fire/smoke seal, consider using additional spray coatings.

9 Beware of inadvertently creating a vapor barrier finish in a location or plane where one does not belong-vinyl wall covering on an exterior drywall surface, for example.

Richard Keleher, AIA, CSI, LEED, is senior architect at Richard Keleher Architect, Concord, Mass. He can be reached at 978-369-4550 or kel@rkeleher.com.

Judd Peterson, AIA, is president of Judd/Allen Group, Edina, Minn. He can be reached at 952-224-5050 or jpeterson@juddallen.com.



author: Richard Keleher and Judd Peterson

Building Design and Construction. Copyright © 2007 Reed Business Information, a division of Reed Elsevier Inc. All rights reserved.

Featured Local Company

Studio A Architecture

502-589-8007
1371 Bardstown Road
Louisville, KY
www.studioaarch.com

Related Local Events
ICUEE - International Construction and Utility Equipment Exhibition
Dates: 10/6/2009 - 10/8/2009
Location: Kentucky Fair & Exposition Center
Louisville, KY
View Details

NATDA Trade Show & Convention
Dates: 9/12/2009 - 9/14/2009
Location: Kentucky International Convention Center
Louisville, KY
View Details

Coal Gen Expo 2009
Dates: 8/19/2009 - 8/21/2009
Location: Kentucky International Convention Center
Louisville, KY
View Details