AC Load Monitor Baltimore MD

A simple circuit monitors the elapsed time over which a line-connected ac load energizes. You can then access the elapsed-time count over a standard one-wire protocol.

Local Companies

Discount Computer Service
410-366-7300
2421 Maryland Ave
Baltimore, MD
Computer Harbor
410-576-1118
1123 Light St
Baltimore, MD
Arknet Computers
410-945-9500
4607 Edmondson Ave
Baltimore, MD
Computer Salvage
410-485-2540
4509 White Ave
Baltimore, MD
Computer Distribution Services Inc
410-864-3303
1811 Portal St
Baltimore, MD
East Coast Micro
410-536-0600
3916 Vero Road Suite F
Baltimore, MD
SysQuick Computers and Support
443-231-5627
802 Gleneagles Court
Baltimore, MD
Better Byte Computer Co
410-444-3730
7405 Harford RD
Baltimore, MD
Superior PC Services
301-318-9127
8010 Somerville Lane
Elkridge, MD
Computer Harbor
(410) 576-1118
1123 Light St
Baltimore, MD

provided by: EDN

A simple circuit monitors the elapsed time over which a line-connected ac load energizes (). You can then access the elapsed-time count over a standard one-wire protocol. When you energize the ac load, the optoisolator provides pulses at the ac-line frequency to the input of the one-wire counter, a DS2423 IC. Thus, the counter continuously increments whenever you energize the load. Resistors R1 and R2 limit the current, and diode D1 protects the optoisolator from reverse-polarity voltages during the negative half of the line cycle.

As an example, the circuit can monitor the duration of operating intervals for a 240V-ac well pump, thereby giving an indirect measure of the amount of water the well pumps and the approximate amount of power it consumes. The one-wire master counter-a Linux-based PC, for example-reads the elapsed count once per minute. Any change in the count from one reading to the next indicates that the pump is energized and running, and you calculate the length of time in seconds by simply taking the difference in counter values divided by the line frequency-60 Hz, in this case. The time in seconds equals the new count minus the old count divided by 60 Hz.

The circuit can monitor a water heater, a furnace, an air-conditioning unit, or any other ac-connected load. You may need to adjust the R1 and R2 values to accommodate line voltages other than 240V ac or the characteristics of other optoisolators. You can also monitor two independent loads by attaching a second optoisolator circuit to the Counter B input of a single DS2423.



author: Michael Petersen, Maxim Integrated Products, Sunnyvale, CA

EDN. Copyright © 2007 Reed Business Information, a division of Reed Elsevier Inc. All rights reserved.

Featured Local Company

Discount Computer Service

410-366-7300
2421 Maryland Ave
Baltimore, MD
http://www.discountcs.com

Related Local Event
Free Computer Classes @ Martin Luther King Jr. Memorial Library
Dates: 7/5/2009 - 7/5/2009
Location: MLK Jr. Memorial Library
Washington, DC
View Details