AC Load Monitor Birmingham AL

A simple circuit monitors the elapsed time over which a line-connected ac load energizes. You can then access the elapsed-time count over a standard one-wire protocol.

Local Companies

Computer Image
205-933-8970
2012 Magnolia Ave
Birmingham, AL
Compaq HP Lyons Computers
205-251-5977
722 37th St S
Birmingham, AL
Perry Computer Services
205-870-7044
1722-B 28th Ave South
Birmingham, AL
Alltech Computer Works
205-290-0215
240 Oxmoor Cir
Birmingham, AL
FAR COMPUTERS
205-783-9800
2134 Warrior Rd
Birmingham, AL
Computer 4 U
205-788-5200
2254 Bessemer Rd Ste 100
Birmingham, AL
TKS Turn-Key Solutions Inc
205-403-8833
104 Owens Pkwy Ste A
Birmingham, AL
American Computer Consultants Inc
205-987-8711
2496 Valleydale Rd
Birmingham, AL
ilektroniksCom corp
(205) 267-2781
716 3rd ST NE
Alabaster, AL
It Express
(205) 263-0090
6 Office Park Cir
Birmingham, AL

provided by: EDN

A simple circuit monitors the elapsed time over which a line-connected ac load energizes (). You can then access the elapsed-time count over a standard one-wire protocol. When you energize the ac load, the optoisolator provides pulses at the ac-line frequency to the input of the one-wire counter, a DS2423 IC. Thus, the counter continuously increments whenever you energize the load. Resistors R1 and R2 limit the current, and diode D1 protects the optoisolator from reverse-polarity voltages during the negative half of the line cycle.

As an example, the circuit can monitor the duration of operating intervals for a 240V-ac well pump, thereby giving an indirect measure of the amount of water the well pumps and the approximate amount of power it consumes. The one-wire master counter-a Linux-based PC, for example-reads the elapsed count once per minute. Any change in the count from one reading to the next indicates that the pump is energized and running, and you calculate the length of time in seconds by simply taking the difference in counter values divided by the line frequency-60 Hz, in this case. The time in seconds equals the new count minus the old count divided by 60 Hz.

The circuit can monitor a water heater, a furnace, an air-conditioning unit, or any other ac-connected load. You may need to adjust the R1 and R2 values to accommodate line voltages other than 240V ac or the characteristics of other optoisolators. You can also monitor two independent loads by attaching a second optoisolator circuit to the Counter B input of a single DS2423.