AC Load Monitor Buffalo NY

A simple circuit monitors the elapsed time over which a line-connected ac load energizes. You can then access the elapsed-time count over a standard one-wire protocol.

Local Companies

Personal Computers, Inc.
(716) 856-7181
703 Washington St.
Buffalo, NY
ACP Technologies
(716) 674-8880
950-A Union Rd., Ste. 504
West Seneca, NY
Buffalo Computing Solutions, Inc.
(716) 852-0523
6325 Sheridan Dr.
Williamsville, NY
Azerty, A Division of United Stationers Supply Co.
(716) 662-0200
13 Centre Dr.
Orchard Park, NY
All-In-One Computer Services
905-228-1334
8712 Champlain Drive
Niagara Falls, ON
Niagara Electronics
905-357-4305
7116 McLeod Road
Niagara Falls, ON
Silvertown Electronics
905-358-0466
4597 Queen Street
Niagara Falls, ON
Centurycomputers.ca
289-438-4451
6954 Lundy's Lane
Niagara Falls, ON
Software First Computers Ltd
905-374-6381
5717 Brookfield Avenue
Niagara Falls, ON
Bordun Bob
905-356-1881
8768 McGarry Drive
Niagara Falls, ON

provided by: EDN

A simple circuit monitors the elapsed time over which a line-connected ac load energizes (). You can then access the elapsed-time count over a standard one-wire protocol. When you energize the ac load, the optoisolator provides pulses at the ac-line frequency to the input of the one-wire counter, a DS2423 IC. Thus, the counter continuously increments whenever you energize the load. Resistors R1 and R2 limit the current, and diode D1 protects the optoisolator from reverse-polarity voltages during the negative half of the line cycle.

As an example, the circuit can monitor the duration of operating intervals for a 240V-ac well pump, thereby giving an indirect measure of the amount of water the well pumps and the approximate amount of power it consumes. The one-wire master counter-a Linux-based PC, for example-reads the elapsed count once per minute. Any change in the count from one reading to the next indicates that the pump is energized and running, and you calculate the length of time in seconds by simply taking the difference in counter values divided by the line frequency-60 Hz, in this case. The time in seconds equals the new count minus the old count divided by 60 Hz.

The circuit can monitor a water heater, a furnace, an air-conditioning unit, or any other ac-connected load. You may need to adjust the R1 and R2 values to accommodate line voltages other than 240V ac or the characteristics of other optoisolators. You can also monitor two independent loads by attaching a second optoisolator circuit to the Counter B input of a single DS2423.



author: Michael Petersen, Maxim Integrated Products, Sunnyvale, CA