A simple circuit monitors the elapsed time over which a line-connected ac load energizes. You can then access the elapsed-time count over a standard one-wire protocol.

Local Companies

Apple Store
(808) 949-1075
1450 Ala Moana Blvd
Honolulu, HI
Acme Computer Services
(808) 545-1543
1302 Pali Hwy
Honolulu, HI
Oahu Computers
(808) 524-1111
670 Auahi St A4
Honolulu, HI
Personal Touch Computers
(808) 524-7253
311 Keawe St
Honolulu, HI
Data 1
(808) 534-0730
547 Halekauwila St
Honolulu, HI
Art & Science
(808) 942-1160
2615 S King St
Honolulu, HI
Blue Planet Software
(808) 539-3900
2800 Woodlawn Dr
Honolulu, HI
Best Buy
(808) 525-7182
478 Alakawa St
Honolulu, HI
Ezrez Software Inc
(808) 735-7777
3465 Waialae Ave
Honolulu, HI
Hawaii Kai Computer Guy
(808) 356-0672
PO Box 26262
Honolulu, HI

provided by: EDN

A simple circuit monitors the elapsed time over which a line-connected ac load energizes (). You can then access the elapsed-time count over a standard one-wire protocol. When you energize the ac load, the optoisolator provides pulses at the ac-line frequency to the input of the one-wire counter, a DS2423 IC. Thus, the counter continuously increments whenever you energize the load. Resistors R1 and R2 limit the current, and diode D1 protects the optoisolator from reverse-polarity voltages during the negative half of the line cycle.

As an example, the circuit can monitor the duration of operating intervals for a 240V-ac well pump, thereby giving an indirect measure of the amount of water the well pumps and the approximate amount of power it consumes. The one-wire master counter-a Linux-based PC, for example-reads the elapsed count once per minute. Any change in the count from one reading to the next indicates that the pump is energized and running, and you calculate the length of time in seconds by simply taking the difference in counter values divided by the line frequency-60 Hz, in this case. The time in seconds equals the new count minus the old count divided by 60 Hz.

The circuit can monitor a water heater, a furnace, an air-conditioning unit, or any other ac-connected load. You may need to adjust the R1 and R2 values to accommodate line voltages other than 240V ac or the characteristics of other optoisolators. You can also monitor two independent loads by attaching a second optoisolator circuit to the Counter B input of a single DS2423.



author: Michael Petersen, Maxim Integrated Products, Sunnyvale, CA

EDN. Copyright © 2007 Reed Business Information, a division of Reed Elsevier Inc. All rights reserved.