AC Load Monitor Miami FL

A simple circuit monitors the elapsed time over which a line-connected ac load energizes. You can then access the elapsed-time count over a standard one-wire protocol.

Local Companies

Aramont computers inc
786-879-4233
7218 nw 31st
miami, FL
Aramont computers inc
786-879-4233
7218 nw 31st
miami, FL
Acl Computers Inc
(305) 826-5000
1711 W 38th Pl
Hialeah, FL
Best Buy
(305) 819-0722
4001 W 20th Ave
Hialeah, FL
E Way
(305) 825-8878
5580 W 16th Ave
Hialeah, FL
Complete Business Systems CBS
(305) 591-8001
14101 Commerce Way
Hialeah, FL
KJMS Technologies Inc.
(954) 734-2829
3350 SW 148th Ave
Miramar, FL
Mendelson Consulting
954-447-0250
18501 Pines Blvd
Pembroke Pines, FL
Pcnet System Inc
(305) 599-0247
7225 NW 25th St
Miami, FL
Computer Parts Repair & Service
(786) 845-8323
6951 NW 82nd Ave
Miami, FL

 

provided by: EDN

A simple circuit monitors the elapsed time over which a line-connected ac load energizes (). You can then access the elapsed-time count over a standard one-wire protocol. When you energize the ac load, the optoisolator provides pulses at the ac-line frequency to the input of the one-wire counter, a DS2423 IC. Thus, the counter continuously increments whenever you energize the load. Resistors R1 and R2 limit the current, and diode D1 protects the optoisolator from reverse-polarity voltages during the negative half of the line cycle.

As an example, the circuit can monitor the duration of operating intervals for a 240V-ac well pump, thereby giving an indirect measure of the amount of water the well pumps and the approximate amount of power it consumes. The one-wire master counter-a Linux-based PC, for example-reads the elapsed count once per minute. Any change in the count from one reading to the next indicates that the pump is energized and running, and you calculate the length of time in seconds by simply taking the difference in counter values divided by the line frequency-60 Hz, in this case. The time in seconds equals the new count minus the old count divided by 60 Hz.

The circuit can monitor a water heater, a furnace, an air-conditioning unit, or any other ac-connected load. You may need to adjust the R1 and R2 values to accommodate line voltages other than 240V ac or the characteristics of other optoisolators. You can also monitor two independent loads by attaching a second optoisolator circuit to the Counter B input of a single DS2423.



author: Michael Petersen, Maxim Integrated Products, Sunnyvale, CA

EDN. Copyright © 2007 Reed Business Information, a division of Reed Elsevier Inc. All rights reserved.

Featured Local Company

Aramont computers inc

786-879-4233
7218 nw 31st
miami, FL

Related Local Events
Wednesday Evening Referral Group
Dates: 1/6/2010 - 1/8/2010
Location: WineStyles
Coral Springs, FL
View Details

Afternoon Chamber Referral Group
Dates: 2/4/2010 - 2/4/2010
Location: The Coral Springs Chamber Office
Coral Springs, FL
View Details

Wednesday Evening Referral Group
Dates: 2/17/2010 - 2/17/2010
Location: WineStyles
Coral Springs, FL
View Details

Morning Chamber Referral Group Meeting
Dates: 3/11/2010 - 2/11/2010
Location: La Quinta Hotel
Coral Springs, FL
View Details

Morning Chamber Referral Group Meeting
Dates: 3/25/2010 - 3/25/2010
Location: La Quinta Hotel
Coral Springs, FL
View Details