AC Load Monitor Phoenix AZ

A simple circuit monitors the elapsed time over which a line-connected ac load energizes. You can then access the elapsed-time count over a standard one-wire protocol.

Local Companies

Dale's Arizona Wholesales, LLC.
602-956-1727
1919 east mcdowell road
phoenix, AZ
Designing Cable Solutions
(602) 866-0227
2440 W. Mission
Phoenix, AZ
IT Partners
(602) 296-6103
2828 N. Central Ave
Phoenix, AZ
Onsite Technical Services, LLC
623203-9329
3039 W. Peoria Ave C102-180
Phoenix, AZ
Tec-Way
602524-7203
Phoenix, AZ
First In First Out
(623) 934-7000
6611 W. Peoria
Glendale, AZ
Electronics Boutique
480-945-8844
7014 E Camelback Rd
Scottsdale, AZ
Team Logic IT - Northwest Valley
(602) 346-2750
16841 North 31st Avenue
Phoenix, AZ
Data Doctors Computer Services
480-556-9400
6929 N Hayden RD
Scottsdale, AZ
GP Audio
602628-4482
11432 N 93rd Ave
Peoria, AZ

provided by: EDN

A simple circuit monitors the elapsed time over which a line-connected ac load energizes (). You can then access the elapsed-time count over a standard one-wire protocol. When you energize the ac load, the optoisolator provides pulses at the ac-line frequency to the input of the one-wire counter, a DS2423 IC. Thus, the counter continuously increments whenever you energize the load. Resistors R1 and R2 limit the current, and diode D1 protects the optoisolator from reverse-polarity voltages during the negative half of the line cycle.

As an example, the circuit can monitor the duration of operating intervals for a 240V-ac well pump, thereby giving an indirect measure of the amount of water the well pumps and the approximate amount of power it consumes. The one-wire master counter-a Linux-based PC, for example-reads the elapsed count once per minute. Any change in the count from one reading to the next indicates that the pump is energized and running, and you calculate the length of time in seconds by simply taking the difference in counter values divided by the line frequency-60 Hz, in this case. The time in seconds equals the new count minus the old count divided by 60 Hz.

The circuit can monitor a water heater, a furnace, an air-conditioning unit, or any other ac-connected load. You may need to adjust the R1 and R2 values to accommodate line voltages other than 240V ac or the characteristics of other optoisolators. You can also monitor two independent loads by attaching a second optoisolator circuit to the Counter B input of a single DS2423.



author: Michael Petersen, Maxim Integrated Products, Sunnyvale, CA

EDN. Copyright © 2007 Reed Business Information, a division of Reed Elsevier Inc. All rights reserved.

Featured Local Company

Dale's Arizona Wholesales, LLC.

602-956-1727
1919 east mcdowell road
phoenix, AZ
arizonawholesales.8m.net

Related Local Events
Dec Membership Luncheon
Dates: 12/9/2009 - 12/9/2009
Location: Rio Vista Recreation Center
Peoria, AZ
View Details

Oct Membership Luncheon
Dates: 10/14/2009 - 10/14/2009
Location: Rio Vista Recreation Center
Peoria, AZ
View Details