AC Load Monitor San Antonio TX

A simple circuit monitors the elapsed time over which a line-connected ac load energizes. You can then access the elapsed-time count over a standard one-wire protocol.

Local Companies

Compusa
(210) 321-2575
820 E Rector St
San Antonio, TX
Computer Services Incorporated
(210) 832-0941
1600 Neloop410
San Antonio, TX
Asap Network Services
(210) 921-1122
San Antonio, TX
Guaranteed Computer Repairs
(210) 212-6466
514 N Mesquite St
San Antonio, TX
B E A Innovations
(210) 340-6757
119 E Rhapsody Dr
San Antonio, TX
Computer Shop the
(210) 615-7671
4335 Vance Jackson Rd
San Antonio, TX
Amenity Computer Services Inc
(210) 647-0125
7126 Eckhert Rd
San Antonio, TX
Www Computermds
(210) 979-9966
San Antonio, TX
Tellus Computer Solutions
(210) 404-1700
12053 Starcrest Dr
San Antonio, TX
Asap Computer Services
(210) 415-2753
13423 Blanco Rd
San Antonio, TX

provided by: EDN

A simple circuit monitors the elapsed time over which a line-connected ac load energizes (). You can then access the elapsed-time count over a standard one-wire protocol. When you energize the ac load, the optoisolator provides pulses at the ac-line frequency to the input of the one-wire counter, a DS2423 IC. Thus, the counter continuously increments whenever you energize the load. Resistors R1 and R2 limit the current, and diode D1 protects the optoisolator from reverse-polarity voltages during the negative half of the line cycle.

As an example, the circuit can monitor the duration of operating intervals for a 240V-ac well pump, thereby giving an indirect measure of the amount of water the well pumps and the approximate amount of power it consumes. The one-wire master counter-a Linux-based PC, for example-reads the elapsed count once per minute. Any change in the count from one reading to the next indicates that the pump is energized and running, and you calculate the length of time in seconds by simply taking the difference in counter values divided by the line frequency-60 Hz, in this case. The time in seconds equals the new count minus the old count divided by 60 Hz.

The circuit can monitor a water heater, a furnace, an air-conditioning unit, or any other ac-connected load. You may need to adjust the R1 and R2 values to accommodate line voltages other than 240V ac or the characteristics of other optoisolators. You can also monitor two independent loads by attaching a second optoisolator circuit to the Counter B input of a single DS2423.



author: Michael Petersen, Maxim Integrated Products, Sunnyvale, CA

EDN. Copyright © 2007 Reed Business Information, a division of Reed Elsevier Inc. All rights reserved.