AC Load Monitor Tampa FL

A simple circuit monitors the elapsed time over which a line-connected ac load energizes. You can then access the elapsed-time count over a standard one-wire protocol.

Local Companies

electric
(813) 410-6269
3819 w gray st
tampa, FL
TechMonster
813-231-3401
8834 N 56th St
Tampa, FL
SUPER PC
(813) 579-5505
P.O. Box 391
Riverview, FL
Apartment Express Corporate
727-563-9505
10901 Brighton Bay Blvd NE
St. Petersburg, FL
Desktop Advantage, Inc.
(727) 532-3800
15500 Roosevelt Blvd. #305
Clearwater, FL
Pyramid Computer
727-522-3995
5944 34th St N
St. Petersburg, FL
R W U International Computer
727-341-0694
169 Dr Martin Luther King Jr St N
St. Petersburg, FL
St Pete Computers
727-327-7559
501 5th Ave NE
St. Petersburg, FL
Genie Computer Systems
727-322-9474
3433 9th Ave N
St. Petersburg, FL
True North Systems
727-544-0990
5748 54th Ave N
St. Petersburg, FL

provided by: EDN

A simple circuit monitors the elapsed time over which a line-connected ac load energizes (). You can then access the elapsed-time count over a standard one-wire protocol. When you energize the ac load, the optoisolator provides pulses at the ac-line frequency to the input of the one-wire counter, a DS2423 IC. Thus, the counter continuously increments whenever you energize the load. Resistors R1 and R2 limit the current, and diode D1 protects the optoisolator from reverse-polarity voltages during the negative half of the line cycle.

As an example, the circuit can monitor the duration of operating intervals for a 240V-ac well pump, thereby giving an indirect measure of the amount of water the well pumps and the approximate amount of power it consumes. The one-wire master counter-a Linux-based PC, for example-reads the elapsed count once per minute. Any change in the count from one reading to the next indicates that the pump is energized and running, and you calculate the length of time in seconds by simply taking the difference in counter values divided by the line frequency-60 Hz, in this case. The time in seconds equals the new count minus the old count divided by 60 Hz.

The circuit can monitor a water heater, a furnace, an air-conditioning unit, or any other ac-connected load. You may need to adjust the R1 and R2 values to accommodate line voltages other than 240V ac or the characteristics of other optoisolators. You can also monitor two independent loads by attaching a second optoisolator circuit to the Counter B input of a single DS2423.



author: Michael Petersen, Maxim Integrated Products, Sunnyvale, CA

EDN. Copyright © 2007 Reed Business Information, a division of Reed Elsevier Inc. All rights reserved.