Achieving PCI Express physical-layer Honolulu HI

To develop effective receiver and transmitter tests for a faster rate, you'll need an understanding of PCI Express specifications as well as knowledge of system architectures, receiver tolerance measurements, stress elements, and transmitter PLL response.

Local Companies

Upena Systems Inc
(808) 792-8880
810 Richards St Ste 955
Honolulu, HI
Networks
(808) 521-4638
925 Bethel St Ste 101
Honolulu, HI
Saibr
(808) 944-9814
900 Fort Street Mall
Honolulu, HI
Infosoft Inc
(808) 838-7780
2810 Paa St Ste A
Honolulu, HI
Mac On Wheels
(808) 585-6281
1149 Bethel St Ste 300
Honolulu, HI
Busch Consulting Inc
(808) 941-3695
PO Box 23360
Honolulu, HI
Counterpoint Hawaii
(808) 531-2226
Honolulu, HI
Paradise Canyon Systems Inc
(808) 521-8411
1003 Bishop St Ste 880
Honolulu, HI
Datanet Systems Inc
(808) 531-2226
Honolulu, HI
Advance Data Corp
(808) 842-6689
1613 Houghtailing St
Honolulu, HI

provided by: Test and Measurement World

With the emergence of the PCI Express 2.0 specification, data-transfer rates doubled from 2.5 GT/s to 5.0 GT/s. To develop effective receiver and transmitter tests for this faster rate, you'll need an understanding of PCI Express specifications as well as knowledge of system architectures, receiver tolerance measurements, stress elements, and transmitter PLL response.

In the 1-hr Webcast ?Pass PCI Express physical layer compliance testing the first time,? Bent Hessen-Schmidt, VP of business development at SyntheSys Research, covers these topics and describes trends in jitter compliance methodology.

Schmidt cites evidence of the difficulties of migrating to PCI Express 2.0: During the first half of 2007, only 10% of 2.5-GT/s PLL designs failed, while 60% of 5-GT/s implementations did. He notes that it is important that both the transmitter and receiver in a common-clock PCI Express design should track the single reference clock nearly identically to prevent clock jitter from contaminating data. He describes using a spectrum analyzer and a clock PLL analyzer to characterize PLL, contending that the clock analyzer provides better accuracy and repeatability.

Schmidt ends by describing dual-port measurements and saying that test methods are evolving to favor the use of sampling instruments as PCI Express speeds move toward 8-GT/s, with the concomitant 20-GHz fifth-order harmonics.



author: Rick Nelson, Chief Editor

Test and Measurement World. Copyright © 2008 Reed Business Information, a division of Reed Elsevier Inc. All rights reserved.