Analog Oscilloscopes Pitfalls Seattle WA

It was a dark and stormy night. It was dark because we had turned off all the lights in the lab as ...

Local Companies

R & R Rentals
(425) 822-4001
10920 Northup Way
Bellevue, WA
Pacific Rim Concrete Pump Inc
(425) 453-8140
3237 110th Ave SE
Bellevue, WA
Eastside Staple & Nail Inc
(425) 641-6191
1917 120th Ave NE
Bellevue, WA
Baldwin and Sons Power Equipment
(425) 453-7673
12700 Bel Red Rd
Bellevue, WA
Dolsen Leasing Company
(425) 454-4002
1940 124th Ave NE
Bellevue, WA
R & R Party Rentals
(425) 688-0099
1923 120th Ave NE
Bellevue, WA
Star Rentals
(425) 885-5522
12900 Northup Way
Bellevue, WA
Aronson Campbell Industrial Supply Inc
(425) 372-2000
1700 136th Pl NE
Bellevue, WA
Grainger Industrial Supply
(425) 643-7754
2221 120th Ave NE
Bellevue, WA
Hydraulic Components
(425) 644-6980
13406 SE 32nd St
Bellevue, WA

provided by: EDN

It was a dark and stormy night. It was dark because we had turned off all the lights in the lab as we anxiously studied the bright-blue-green glow of the oscilloscope, and it was stormy because our prototypes were not cooperating with our troubleshooting efforts, and the boss was getting antsy. (Note that ?antsy? is an anagram of ?nasty.?)

The previous Friday afternoon, all had been working great. Four of our brand-new babies were finally debugged, tucked safely into their card slots, and obediently passing error-free bits back and forth over the backplane and across the optical links. We went home with big smiles and plans for a weekend celebration, thinking that the project was near completion.

On Monday morning, the bit-error counters had climbed to record numbers and were steadily increasing. All the optical-link SNRs (signal-to-noise ratios) were great, but each card insisted on periodically, randomly, and independently flipping bits. The following days of troubleshooting efforts concentrated on the analog optical links. Who ever heard of digital circuits giving this kind of trouble? Digital circuits either work, or they don?t, right?

After chasing down many blind alleys, late one night we finally looked at the buffered-system clock and backplane data on the scope?a Tektronix dual-channel analog job with a nice, bright CRT screen. In the dark of the lab, one sharp-eyed colleague looked at the clock trace and said, ?What?s that?? A little smudge of light had appeared where none belonged.

Cranking up the timebase and vertical scale to position the brightest trace portions off screen (but still with a phosphor glow from reflected electrons), we were able to just discern the ghost of something that was not right. Just after the clock?s falling edge, we observed an occasional small pulse, made very faint by its infrequent occurrence. Bingo!

Today, a digital scope set to ?runt trigger? or ?infinite persistence? would have immediately found this problem, but analog scopes from back then did not have those features. Finding problems like this took a lot of effort and perseverance, combined with good eyesight and a darkened lab at night.

It turned out that placing the card?s backplane interface buffers 3 in. away from the connector formed stubs. As more and more of these cards loaded the parallel backplane bus, the problem got worse. The backplane clock edges were ringing under the stub loading to the point at which the ringing occasionally passed the buffer?s digital threshold and added an extra clock cycle.

We respun the card, and it worked great.

Glen Chenier is a former telecom engineer and is now a design consultant. You can reach him at glen@teetertottertreestuff.com. Like Glen, you can share your Tales from the Cube and receive $200. Contact edn.editor@reedbusiness.com.



author: By Glen Chenier, consultant

EDN. Copyright © 2008 Reed Business Information, a division of Reed Elsevier Inc. All rights reserved.

Featured Local Company

R & R Rentals

(425) 822-4001
10920 Northup Way
Bellevue, WA
http://www.rr-rentals.com