Attaching Deck Ledgers Houston TX

It is common building practice to use flashing to keep moisture from getting between the house and the ledger. The Uniform Building Code requires flashing, and many contractors meet the requirement by installing an L-shaped piece of metal. The horizontal leg covers the top of the ledger and the vertical leg goes up the wall and is lapped by the building paper and siding above.

Local Companies

Arbuckle Builders
(713) 662-0422
2311 Dunlavy St
Houston, TX
ricardo
(504) 261-5840
1916
everret, TX
Acadian Builders
(713) 622-7549
3419 Mercer St
Houston, TX
ihp construction
(817) 231-0990
6061bevrly hill dr
Houston, TX
Envirostone Concreta Pavers
832.893.8671
6425 Westheimer Rd.
Houston, TX
Three W Services
713-460-0072
6713 Barney Rd.
Houston, TX
A D Builders & Developers
(713) 780-1112
9900 Westpark Dr
Houston, TX
rosasplastering
832-206-3268
2310breacrest
houston, TX
A F Construction
(713) 491-8605
6702 E Houston Rd
Houston, TX
Texas COncrete Effects Inc.
(832) 573-7136
7702 valley view ln
houston, TX


It is common building practice to use flashing to keep moisture from getting between the house and the ledger. The Uniform Building Code requires flashing, and many contractors meet the requirement by installing an L-shaped piece of metal. The horizontal leg covers the top of the ledger and the vertical leg goes up the wall and is lapped by the building paper and siding above.

Most carpenters install the ledger in the same plane as the joists, so the deck surface ends up an inch or more higher than the horizontal leg of the flashing. This creates a perfect collection zone because if something falls in toward the house, the flashing will prevent it from falling through to the ground. If enough organic matter collects on the flashing, it can induce rot in the adjoining deck board or invade the siding above.

The simplest way to deal with this problem is to use a ledger that is taller than the joists and install it so the top edge will be in the same plane as the deck boards once those are installed.

You still need to flash the connection, but the flashing should come down the wall from behind the siding and building paper, run across the top of the ledger, and end in a lip that laps down the face (see illustration below). —Adapted from “Rot Resistant Deck Details,” by Kim Katwijk, which first appeared in the April 2005 issue ofThe Journal of Light Construction (www.jlconline.com), a sister publication to REMODELING.

No End Date for this image

Debris-Free Ledger

 
  • Save / S

Click here to read full article from Remodeling

Featured Local Company

Arbuckle Builders

(713) 662-0422
2311 Dunlavy St
Houston, TX

Related Local Events
Deepwater Operations Conference & Exhibition (DOF 2009)
Dates: 11/10/2009 - 11/12/2009
Location: Moody Gardens Hotel & Convention Center
Galveston, TX
View Details

American Contract Manufacturers Show (AmCon-Houston)
Dates: 11/4/2009 - 11/5/2009
Location: The Reliant Center at Reliant Park, Houston
Houston, TX
View Details

Digital Exploration and Production
Dates: 10/19/2009 - 10/19/2009
Location: The Omni Galleria, Houston
Houston, TX
View Details

ISA EXPO 2009
Dates: 10/6/2009 - 10/8/2009
Location: Reliant Park
Houston, TX
View Details

Texas Home & Garden Show
Dates: 8/21/2009 - 8/23/2009
Location: George R. Brown Convention Center
Houston, TX
View Details