Avoiding Electrical Hazards on Construction Sites Memphis TN

The most common electrical hazard on today's construction sites is from ground fault electrical shock. In order to reduce shock-related injuries, the OSHA electrical standard requires employers to provide either ground fault circuit interrupters (GFCIs) for receptacle outlets or an assured equipment grounding conductor program. Here are some guidelines to prevent electrical injuries.

Local Companies

SUAREZ ALL
901 502 1544
3906 VERNON AVE
MEMPHIS, TN
ANY & ALL Home Services
901-473-9194
1433 Sandy Betts
Nebsit, MS
Cur-Low Construction
(901) 357-0311
2832 Coleman Rd
Memphis, TN
O B Home Repair & Improvement
(901) 729-2800
Memphis, TN
Ioannes Inc
(901) 365-6597
2506 Mount Moriah Rd
Memphis, TN
A & R Home Improvment
(901) 722-4000
2318 Marble Ave
Memphis, TN
Jd Exteriors Inc
(901) 680-9521
1035 Oakhaven Rd
Memphis, TN
Intergrity Construction
(901) 384-0411
3647 Old Brownsville Rd
Memphis, TN
Best Painting & Wallcovering
(901) 544-9909
147 Jefferson Ave Ste 900
Memphis, TN
Memphis Remodeling & Realty
(901) 794-2443
1090 Lewis St
Memphis, TN


The most common electrical hazard on today's construction sites is from ground fault electrical shock. In order to reduce shock-related injuries, the OSHA electrical standard requires employers to provide either ground fault circuit interrupters (GFCIs) for receptacle outlets or an assured equipment grounding conductor program. Here are some guidelines to prevent electrical injuries.

  • Always use appropriate personal protective equipment, including but not limited to rubber insulating gloves, hoods, sleeves, matting, and blankets.
  • Only use hand tools, electrical tools, and extension cords that are in good repair.
  • De-energize electric power circuits before working near, inspecting, or making repairs.
  • Provide grounding. Service or system ground where the neutral conductor is grounded. Equipment grounding provides a path for current from a tool or machine to the ground. Any live parts of electrical equipment operating 50 volts or more must be guarded to avoid accidental contact.
  • When employees using jackhammers or hand tools do not know the exact location of underground electrical lines, they must wear insulated gloves.
  • De-energize and ground overhead lines before beginning work. Unqualified employees and mechanical equipment must stay at least 10 feet away from these lines.
  • These guidelines are an excerpt from the Tailgate/Toolbox Safety Meetings created by Safety Services in Corona, Calif., a company that provides customized safety training and support for small cons