Charging an Air Conditioner Portland OR

If the air conditioner at home is acting up, chances are that you may need to charge the refrigerant in the unit. Air conditioners normally do not need frequent charging, the situation would arise only in instances where, the refrigerant leaks or some component has been freshly installed or you are assembling a new air conditioning unit from scratch.

Local Companies

MyEnvironmental Consultant.com
503-939-2096
3709 SW Vesta Street
Portland, OR
1-800-GOT-JUNK
503-209-9253
9442 SW Barbur Blvd
Portland, OR
Waste Management of Oregon
(503)331-2221
7227 NE 55th Avenue
Portland, OR
EFI Secured Shredding and Recycling
503-737-2100
4325 N. Commerce Street
Portland, OR
advanced hood cleaning
971-240-3587
9634 se foster rd
portland, OR
Forest Cleaning Inc
503-293-5927
12568 Main St
Tigard, OR
We Clean Everything, Inc.
360-735-7945
4707 NE Minnehaha St #D401
Vancouver, WA
LYNCH Janitorial and Cleaning
(360) 624-5358
P.O. Box 310
Vancouver, WA
LYNCH Janitorial & Cleaning, LLC
360.624.5358
P.O. Box 310
Vancouver, WA
Flawless Keeping
(503) 961-4788
743 SW 17th Way
Troutdale, OR

Provided by: 

If the air conditioner at home is acting up, chances are that you may need to charge the refrigerant in the unit. Air conditioners normally do not need frequent charging, the situation would arise only in instances where, the refrigerant leaks or some component has been freshly installed or you are assembling a new air conditioning unit from scratch. Charging the refrigerant refers to the process of adding or removing a fixed amount of refrigerant from the unit, so it can provide uniform cool air throughout the room or house. Charging the refrigerant also depends on the type of refrigerant the air conditioner uses. A distinction is made between azeotrope and non-azeotrope refrigerants. The former is a blend of different refrigerants which act as a single refrigerant, whereas the latter do not. Hence, azeotrope refrigerants can be topped up, but non-azeotrope refrigerants must be refilled from scratch. Follow the step-by-step instructions given below to find out how you can charge a sluggish air-conditioner.

STEP 2:

For capillary tube fitted systems or in case of inadequate cooling.

Step I - Switch off the compressor.

Step II - Fix the cylinder containing the refrigerant to the centre hose of the pressure gauge.

Step III - Clean or purge the line by throttling the plain gauge regulator as also the cylinder regulator. Close the regulators after the cleaning is complete.

Step IV - Remove the safety cap of the unit's service valve and connect the hose from the pressure gauge to it.

Step V - Slowly open the pressure gauge regulator and throttle open the cylinder regulator. Close the cylinder regulator when the pressure has reached the operating pressure applicable to the unit model. Run the air conditioner to check if the cooling is now adequate and the sight glass is not obscured.

Step VI - If the cooling is still insufficient, switch of the unit and repeat the process in step V, until the optimum level of cooling has been reached.

STEP 3:

For thermostatic expansion valve systems or in case of too much cooling.

Step I - Same as steps I-III above.

Step II - Attach the hose from the compound pressure gauge (in the previous case it was the plain pressure gauge used) to the suction service valve in the air conditioner after removing the protective cap from the valve.

Step III - Open the compound gauge regulator slowly, while throttling the cylinder regulator. The pressure applied should be less than the pressure point at which the refrigerant condenses. Close the cylinder regulator when the operating pressure point on the lower side is reached. Run the air conditioner to check if the cooling intensity has come down and the sight glass is clear. Once the optimal low pressure point is reached, it means that enough charging of the refrigerant is done and the air conditioner will now work properly.

STEP 4:

For a fully emptied unit or a newly assembled air conditioner or a unit where moisture has been removed.

Step I - Switch off the compressor, connect the cylinder hose to the central valve of the pressure gauge and purge the line by simultaneously throttling both the cylinder and gauge regulators. Close the regulators once purging is complete.

Step II - Attach the compound pressure hose from the pressure gauge to the suction service valve of the air conditioner.

Step III - Open the compound pressure regulator slowly and fully open the cylinder regulator. Since the refrigerant is being filled from scratch, continue the process until the full required amount of refrigerant has been added to the system.

Step IV - Run the air conditioner, check for the operating pressure, clear sight glass and the superheat status of the refrigerant.

"Superheat" refers to the temperature at which the refrigerant will return back to the compressor in vapor form. The opposite effect of this is "subcool"; which is the temperature at which the refrigerant condenses to a saturated liquid and flows from the compressor to provide the cooling effect.Charging an air-conditioner is a complex process which requires a good understanding of the way an air conditioner works, how the circulation process works and optimal pressure requirements. If any of these sound complicated or tough to you, then it is better to get the professional expertise of qualified technicians to charge the system or repair any leaks.

Click here to visit HowToDoThings.com

Featured Local Company

MyEnvironmental Consultant.com

503-939-2096
3709 SW Vesta Street
Portland, OR

Related Local Event
AIR & WASTE MANAGEMENT ASSN - A&WMA 102nd ANNUAL EXHIBITION AND CONFERENCE
Dates: 6/16/2009 - 6/19/2009
Location: Oregon Convention Center
Portland, OR
View Details