Delta-Sigma Converters Change The Signal Chains Denver CO

Delta-sigma converters with sinc (sinx/x) digital filters change the signal chain?s complex antiali...

Local Companies

Alternative Ventures Inc Roofing & Gutters
(303) 650-8904
7255 Irving St
Westminster, CO
Westminster Coin Jewelry and Sports Appraisals.Com
(303) 428-9175
6881 Xavier Cir
Westminster, CO
Seamless Gutters LLC
(720) 898-5539
5465 Harlan St
Arvada, CO
Woodcrafters by Design
(303) 487-1870
6102 W 55th Ave
Arvada, CO
R F S Inc
(303) 423-1264
4935 Allison St
Arvada, CO
Suburban Reddi Mix
(303) 421-0720
5400 Fenton St
Arvada, CO
A to Z Pruducts by Timberline
(303) 420-4060
11700 W 58th Av
Arvada, CO
AMX Enterprises LTD
(303) 428-8760
7963 Depew St
Arvada, CO
Aaark Heating Air Conditioning Electrical & Plumbing
(303) 431-8015
5962 Sheridan Blvd
Arvada, CO
Buckingham Rental
(303) 343-9240
1073 S Ironton St
Aurora, CO

provided by: EDN

Delta-sigma converters with sinc (sinx/x) digital filters change the signal chain?s complex antialiasing-filter requirements to a simple, first-order, passive filter. With this ?easy-to-design? circuit, you can tackle the major noise contributors around the delta-sigma modulator?s sampling frequency. The converter?s characteristics that you use in this filter design are the modulator-sampling rate, FS, and output-data rate, FD.

The frequency response of a sinc digital filter looks like a comb (Figure 1). The frequency of the first null in this figure is equal to the FD of the converter. If you look at the frequency response of a sinc filter up to the modulator?s sampling rate, you can see that the sampling frequency is much faster than the converter?s output-data rate.

Because a delta-sigma converter is a sampling system, all noise and signals above one-half of the FS alias back. The sinc digital filter rejects noise over a wide frequency band, but it does not reject system noise around the FS. The amplitude of the noise and signals hovering around the sampling frequency is small, but noise is a reality. The lower bits may fluctuate because you have a high-resolution converter.

The corner frequency of your analog filter is equal to the output-data rate, or FD. Fortunately, this filter has a low-order function, and the appropriate choice is a simple RC filter. If your system has a lot of noise or signals around the region of FS or if the decimation ratio is less than 100, consider using a second-order, lowpass filter.

Place the analog antialiasing filter before the input of the converter. Figure 2 shows the best option for this passive, lowpass filter for a single-channel device, where FD=1/(2?RFLT×CFLT). Because the lowpass filter is a simple RC pair, the values of the filter?s resistors (RFLT/2) are easy to choose as long as the resistor noise from dc to the filter?s corner frequency is less than one-third of the noise that the delta-sigma converter generates. The value of the capacitor (CFLT) should be at least 20 times higher than the input capacitance of the converter. It can be as high as you want, as long as you keep in mind that your filter?s corner frequency is equal to or greater than the converter?s output-data rate.

If you have extraneous noise in your system, you will be pleased with the results of using this antialiasing filter. You may not find noise in your lab conversions, but make sure you anticipate the location of your system. In the field, extraneous and noisy signals may very well just creep into your converter.

Bonnie Baker is a senior applications engineer at Texas Instruments and author of A Baker?s Dozen: Real Analog Solutions for Digital Designers. You can reach her at bonnie@ti.com.



author: by Bonnie Baker

EDN. Copyright © 2008 Reed Business Information, a division of Reed Elsevier Inc. All rights reserved.