Hunting Energy Savings De Pere WI

Replacing outdated incandescent and fluorescent lamps produces dramatic energy savings.

Local Companies

Abts-olutley Handy
920-660-4102
1830 Pink Dogwood Way
Green Bay, WI
Packerland Electric Llc
(920) 336-8600
3684 Packerland Dr
De Pere, WI
J&m Electric
(920) 983-2836
1375 Carrington Ln
De Pere, WI
Concept Services Electrical Contractor
(920) 336-8463
4033 State Highway 57
De Pere, WI
Bridgeport Electric Inc
(920) 336-3732
1998 S Broadway
De Pere, WI
Csi Electric
(920) 336-8463
De Pere, WI
Ideal Electric
(920) 347-9244
1396 Plane Site Blvd
De Pere, WI
Thomas Electric
(920) 336-4648
576 Redbird Cir
De Pere, WI
West Electric Inc
(920) 338-0626
1195 Flightway Dr
De Pere, WI
Kleuskens Electric
(920) 336-3764
1418 Grant St
De Pere, WI

provided by: 

A July 2005 lighting retrofit of the 390-room Baltimore Marriott Hotel Valley Inn cut lighting energy expenditures over 50 percent by replacing outdated incandescent and fluorescent lamps in favor of dimmable, long-life plug-in and screw-in compact fluorescent lamps and high-efficiency T8 linear fluorescent lamps and electronic ballasts.

"We've helped the hotel hit a 50 percent improvement on kilowatt savings alone," says Richard G. Lubinski, President of Ohio-based energy consulting firm Think Energy Management, LLC, a consultant to HEI Hospitality, LLC, the company that owns and manages the property.

Lubinski's firm and HEI collaborated with GE Consumer & Industrial to develop a self-funding energy-efficiency initiative that not only cuts wasteful spending on energy for lighting, but also delivers lower maintenance costs and better quality lighting throughout the hotel.

Back-of-house operations at the hotel, previously illuminated by T12 40-watt linear fluorescent lamps operating on magnetic ballasts, were retrofitted with a highly efficient F28T8 lamp-ballast system that combines F28T8/SP35/UMX/ECO linear fluorescent lamps and electronic ballasts. For about 500 linear fluorescent fixtures, HEI saw light output improvements jump from 4,950 lumens to 5,170 lumens. Color rendering also improved.

Many down-lighting and general lighting applications in hallways, banquet rooms, conference rooms and guestrooms—where up to 200-watt incandescent lamps had been used—now feature dimmable plug-in or screw-in compact fluorescent lamps. A 42-watt CFL, for example, offers up to 72 percent energy savings compared with a 150-watt incandescent lamp used near a guestroom chair.

According to ENERGY STAR, a U.S. Environmental Protection Agency program that helps businesses and individuals protect the environment through superior energy efficiency, if U.S. hotels improved energy performance by 30 percent on average, annualized electricity bill savings would be nearly $1.5 billion. This represents a savings of approximately $365 per available room night per year for every hotel room in the country.

Featured Local Company

Abts-olutley Handy

920-660-4102
1830 Pink Dogwood Way
Green Bay, WI