KEEPING A CLOSE EYE ON CODE CHANGES North Wales PA

They said this trade-off would be used to "partially compensate" for the higher cost of "providing fire sprinkler protection.

Local Companies

OGBIO™
267-475-7422
7827 Bradford St
Philadelphia, PA
Tri - Tronics Inc
(215) 661-9264
North Wales, PA
Ata Security Systems Inc
(717) 263-9237
150 Farm Credit Dr
Chambersburg, PA
Wisch Solar & Security Films
(610) 437-1966
28 N Jerome St
Allentown, PA
Datacom Security Systems
(610) 440-0083
Northampton, PA
Nationwide Security Systems Inc
(215) 745-8800
Huntingdon Valley, PA
Ssa
(724) 834-3373
Greensburg, PA
Direct Security Systems
(814) 836-1400
Erie, PA
Short Brothers Alarms
(610) 469-0915
196 Stauffer Rd
Pottstown, PA
Holicong Locksmiths & Central Security Inc
(215) 348-5031
1968 Holicong Rd
Holicong, PA

provided by: 

STAYING INVOLVED IN THE BUILDING CODE PROCESS

Q How can I be involved in the building code process at some level?

A Watch for code changes being proposed in your state. By law, every code change is required to be posted in the local newspaper before it takes effect. Don't assume that others in the industry know about pending code adoptions, amendments or proposals. For example, the 2006 edition of the International Residential Code (IRC) had an amendment proposal called RB85-04/05 that made it all the way to the Final Action Hearings before being defeated. This amendment would have allowed smoke detection to be eliminated from the bedrooms of all one- and two-family homes, if a sprinkler system was installed.

They said this trade-off would be used to "partially compensate" for the higher cost of "providing fire sprinkler protection." How cheap has life become to these people that a savings of $30 to eliminate smoke detection to help offset a $3,000 sprinkler system makes sense? The proponents actually claimed that sprinklers were enough to save anyone who was asleep in the room of fire origin.

The sprinkler industry seems to have made some strange converts, since this particular amendment was proposed and supported by the Florida Fire Marshals and Inspectors Association. Also disturbing was their supporting justification that referred to "a study" that found "only 72 to 76% of people wake up when an alarm of 60dB was received" and used this as reasoning to try and eliminate smoke detection from sleeping areas. While that statistic may or may not be true, it is immaterial. The facts are, all UL listed smoke alarms are manufactured to produce an alarm of at least 85dB (measured at ten feet from the device) and that NFPA 72 requires a fire alarm system to cause an alarm of at least 75 dB measured "at the pillow." The report didn't mention that sprinklers are most effective when installed in concert with a fire alarm warning system. (You can read about this latest proposed trade-off attempt online at: www.iccsafe.org/cs/codes/2004-05cycle/ProposedChanges/IRCBE-2.pdf)

Our alarm and detection industry continues to be assaulted with misleading statements and twisted statistics. Unless we are pro-active, bad ordinances will go through unchallenged.

OBSTRUCTED VIEW

Q Who is correct? I say I can place wall mounted 15 candela strobe lights around the perimeter of a large (148 ft. x 160 ft.) office space, and place them up to 100 feet apart, but the contractor says that the cloth covered cubicle-type divider specified to be installed will obstruct their view.

A Your office space half-walls don't officially become ADAAG "obstructions" until they are 6 feet tall. Your 5 foot divider doesn't qualify. Consider asking the owner if anyone that will be working there is hearing impaired. Title I of ADA would require that the owner provide "reasonable accommodation" for that employee's workspace. If this is the case, get a change order to provide ceiling mounted strobe lights.

GREG KESSINGER, SET, CFPS, president of an alarm installing company since 1981, teaches NICET training classes to fire alarm system designers and installers and continuing education seminars for Ohio's fire alarm inspectors. You can reach him at 888-910-2272; e-mail: Greg@firealarm.org; or visit his website at www.FireAlarm.org.

author: By Greg Kessinger


Featured Local Company

OGBIO™

Biometric products and service center

267-475-7422
7827 Bradford St
Philadelphia, PA
http://www.ogbio.com

OGBIO is US-International based company which specializes in biometric products and services. We are committed to offer the honorable full service to the community by providing the innovation professional products and service with the best efforts and excellent outcome so that everyone enjoys the safest life and make the most convenient life.

OGBIO hopes to be memorized as the professional top brand of Biometric Security Products which change the world to the safest circumstances, and to be admired at our values, deeds and the every process in our lives as an exemplary ideal society. Each one of us is a precious individual, who deserves to be respected and encouraged. The company and all members protect and develop each other as a social family pursuing each other’s growth and happiness.

Related Local Events
TRACC Luncheon at Moravian Hall Square - Preparing for Your Future and Financial Security
Dates: 11/19/2009 - 11/19/2009
Location: Moravian Hall Square
Nazareth, PA
View Details

Public Safety Training Facility Grand Opening
Dates: 10/26/2009 - 11/1/2009
Location: Bensalem Township Country Club's Open House
Bensalem, PA
View Details

Member Lunch
Dates: 10/20/2009 - 10/20/2009
Location: Ruffini’s Restaurant
Thorndale, PA
View Details

Public Safety Training Facility Grand Opening
Dates: 10/19/2009 - 10/25/2009
Location: Bensalem Township Country Club's Open House
Bensalem, PA
View Details