POWER-LIMITED FIRE ALARM CABLES CONTINUED Baltimore MD

The following contains home security information you should know about power-limited fire alarm cables. Read on if you or a loved one is interested in home improvement and security in Baltimore.

Local Companies

Home Security Baltimore
240-547-1235
476 E Fayette St
Baltimore, MD
Kipp Security Systems
410-235-9900
3600 Clipper Mill Rd Suite 105
Baltimore, MD
Crown Security System
410-235-5577
2530 North Charles St., Suite 200
Baltimore, MD
Iverify US
410-235-2033
2831 Greenmount Ave
Baltimore, MD
Netversant Solutions Integrated Security Control Systems
410-522-3700
900 N Lehigh St
Baltimore, MD
Baltimore Alarm & Security
410-358-8600
5314 Reisterstown
Baltimore, MD
Adt Security Services Incorporated
410-448-4238
5207 Bosworth Ave
Baltimore, MD
A B Security Systems
410-488-2248
4134 Parkside Dr
Baltimore, MD
Safeguard Security System
410-284-2042
7825 E Baltimore St
Baltimore, MD
A 1 Security Systems
410-653-9568
5 Stridesham Ct
Baltimore, MD

provided by: 

DIGGING FOR AN ANSWER TO UNDERGROUND CABLE

Q As a follow up to last month's questions on Power-Limited Fire Alarm Cables (FPL), is there a requirement to use FPL in conduit that is installed underground from one building to another building? The Authority Having Jurisdiction (AHJ) says I always have to use "fire alarm cable."

A No. Type FPL is meant to be installed exposed in a building, and when following the rules from Article 760.15, Part B, conduit isn't necessary. To be given the FPL designation is to indicate that the conductor's insulation/jacket will be "resistant to the spread of fire," which is not a factor with buried cable.

Therefore, since FPL is not approved for "wet locations" and there is no such thing as "direct burial FPL cable," you are left with choosing one of three methods. Which method you choose will probably depend on how much you like to dig:

METHOD #1.METHOD #2.METHOD #3.
Use Direct Burial Cables or Conductors.Use Nonmetallic Raceways Listed for Direct Burial Without Concrete Encasement or Other Approved Raceways.Use Rigid Metal Conduit or Intermediate Metal Conduit.
Only copper conductors are permitted for fire alarm use (stranded or solid).Cables and insulated conductors installed in enclosures or raceways in underground installations shall be listed for use in wet locations.Cables and insulated conductors installed in enclosures or raceways in underground installations shall be listed for use in wet locations.
310.7 Direct burial cables or conductors. Conductors used for direct burial applications shall be of a type identified for such use.i.e. MTW, RHW, RHW-2, TW, THW, THW-2, THHW, THHW-2, THWN, THWN-2, XHHW, XHHW-2, ZW (or Direct Burial cables).i.e. MTW, RHW, RHW-2, TW, THW, THW-2, THHW, THHW-2, THWN, THWN-2, XHHW, XHHW-2, ZW (or Direct Burial cables).
Bury it at least 24 inches deep.Bury it at least 18 inches deep.Bury it at least 6 inches deep.

GREG KESSINGER, SET, CFPS, president of an alarm installing company since 1981, teaches NICET training classes to fire alarm system designers and installers and continuing education seminars for Ohio's fire alarm inspectors. You can reach him at 888-910-2272; e-mail: Greg@firealarm.org; or visit his website at www.FireAlarm.org.

author: By Greg Kessinger


Featured Local Company

Home Security Baltimore

240-547-1235
476 E Fayette St
Baltimore, MD
http://www.homesecurity-baltimore.com

Related Local Events
ICC - International Code Council Annual Conference
Dates: 11/1/2009 - 11/4/2009
Location: Baltimore Convention Center
Baltimore, MD
View Details

MID-ATLANTIC ALL HAZARDS FORUM & EXHIBITION 2009
Dates: 11/1/2009 - 11/1/2009
Location: Baltimore Convention Center
Baltimore, MD
View Details

SANS WhatWorks in Virtualization Security Summit
Dates: 8/17/2009 - 8/21/2009
Location: Fairmont Washington DC
Washington, DC
View Details

International Aid & Trade Event
Dates: 7/9/2009 - 7/10/2009
Location: Ronald Reagan Building & International Trade Center
Washington, DC
View Details