POWER-LIMITED FIRE ALARM CABLES CONTINUED Phoenix AZ

The following contains home security information you should know about power-limited fire alarm cables. Read on if you or a loved one is interested in home improvement and security in Phoenix.

Local Companies

Rosewood Security, Inc
(623) 363-5536
1702 E. Highland
Phoenix, AZ
Fields Consulting Group Inc
(602) 944-3901
927 W. Hatcher
Phoenix, AZ
HSM Security Services
602-674-6105
2440 W Mission Ln #16
Phoenix, AK
Onsite Technical Services, LLC
(623) 203-9329
3039 W. Peoria
Phoenix, AZ
Tec-Way
(602) 524-7203
Bret Phaneuf
Phoenix, AZ
Protection One Security
(602) 350-1212
333 W. Indian School
Phoenix, AZ
Home Security Experts Scottsdale
602-903-3533
7776 E 1st Ave
Scottsdale, AZ
PRO Alarm
480-921-3345
6200 E Thomas Rd
Scottsdale, AZ
Spy Shop of Arizona
480-990-1290
8726 E Piccadilly Rd
Scottsdale, AZ
The Security Blanket
480-945-6522
8438 E Vernon Ave
Scottsdale, AZ

provided by: 

DIGGING FOR AN ANSWER TO UNDERGROUND CABLE

Q As a follow up to last month's questions on Power-Limited Fire Alarm Cables (FPL), is there a requirement to use FPL in conduit that is installed underground from one building to another building? The Authority Having Jurisdiction (AHJ) says I always have to use "fire alarm cable."

A No. Type FPL is meant to be installed exposed in a building, and when following the rules from Article 760.15, Part B, conduit isn't necessary. To be given the FPL designation is to indicate that the conductor's insulation/jacket will be "resistant to the spread of fire," which is not a factor with buried cable.

Therefore, since FPL is not approved for "wet locations" and there is no such thing as "direct burial FPL cable," you are left with choosing one of three methods. Which method you choose will probably depend on how much you like to dig:

METHOD #1.METHOD #2.METHOD #3.
Use Direct Burial Cables or Conductors.Use Nonmetallic Raceways Listed for Direct Burial Without Concrete Encasement or Other Approved Raceways.Use Rigid Metal Conduit or Intermediate Metal Conduit.
Only copper conductors are permitted for fire alarm use (stranded or solid).Cables and insulated conductors installed in enclosures or raceways in underground installations shall be listed for use in wet locations.Cables and insulated conductors installed in enclosures or raceways in underground installations shall be listed for use in wet locations.
310.7 Direct burial cables or conductors. Conductors used for direct burial applications shall be of a type identified for such use.i.e. MTW, RHW, RHW-2, TW, THW, THW-2, THHW, THHW-2, THWN, THWN-2, XHHW, XHHW-2, ZW (or Direct Burial cables).i.e. MTW, RHW, RHW-2, TW, THW, THW-2, THHW, THHW-2, THWN, THWN-2, XHHW, XHHW-2, ZW (or Direct Burial cables).
Bury it at least 24 inches deep.Bury it at least 18 inches deep.Bury it at least 6 inches deep.

GREG KESSINGER, SET, CFPS, president of an alarm installing company since 1981, teaches NICET training classes to fire alarm system designers and installers and continuing education seminars for Ohio's fire alarm inspectors. You can reach him at 888-910-2272; e-mail: Greg@firealarm.org; or visit his website at www.FireAlarm.org.

author: By Greg Kessinger


Featured Local Company

Rosewood Security, Inc

(623) 363-5536
1702 E. Highland
Phoenix, AZ

Related Local Events
Chandler Chamber Women's Council Meeting
Dates: 12/1/2009 - 12/1/2009
Location: Radisson Hotel Phoenix/Chandler
Chandler, AZ
View Details

Business Center Seminar
Dates: 12/17/2009 - 12/17/2009
Location: Chandler Chamber of Commerce
Chandler, AZ
View Details

Jan Membership Luncheon
Dates: 1/13/2010 - 1/13/2010
Location: Rio Vista Recreation Center
Peoria, AZ
View Details

Workplace Safety Meeting
Dates: 11/4/2009 - 11/4/2009
Location: Chandler Chamber of Commerce
Chandler, AZ
View Details

Women's Council Meeting
Dates: 11/3/2009 - 11/3/2009
Location: Chandler Chamber of Commerce
Chandler, AZ
View Details