PROGRAMMING NOTIFICATION DEVICES North Wales PA

Finding this passage is much more difficult in the 2002 edition of NFPA 72.

Local Companies

OGBIO™
267-475-7422
7827 Bradford St
Philadelphia, PA
Tri - Tronics Inc
(215) 661-9264
North Wales, PA
Fidelity Burglar & Fire Alarm Co Inc
(610) 341-9111
Wayne, PA
Protech Security Corp
(215) 672-9115
Warminster, PA
Kuga M S Co
(724) 266-8343
435 Merchant St
Ambridge, PA
A R M Security Systems
(724) 222-3761
Washington, PA
Dynamark Security Center
(570) 327-3000
201 Basin St
Williamsport, PA
Structured Resources Inc
(610) 358-3550
1625 Valley Rd
Newtown Square, PA
Vector Security
(717) 285-0050
3549 Hempland Rd
Lancaster, PA
Rutkowski Joseph W
(412) 795-0945
45 Kellywood Ct
New Kensington, PA

provided by: 

TAKE 5

Q: I can't find where NFPA 72 2002 allows me to program my notification appliances to time out after five minutes.

A: In the 1993, 1996, and 1999 editions of NFPA 72, the section covering this option is found in 1-5.4.8. But technically, NFPA 72 doesn't allow the alarm to be automatically silenced. Instead, NFPA 72 only allows the AHJ to decide if they will permit this feature to be used: "If automatically turning off the alarm notification appliances is permitted by the authority having jurisdiction, the alarm shall not be turned off in less than 5 minutes."

However, the five minute minimum seems to be merely a suggestion since the next line provides an exception for the AHJ to allow even less time: "If otherwise permitted by the authority having jurisdiction, the 5-minute requirement shall not apply."

Finding this passage is much more difficult in the 2002 edition of NFPA 72. First the passage was changed from Chapter 1 to Chapter 4 and then divided into six sections, instead of three. Also, whenever a code passage is changed from the previous edition, a vertical line is required to be placed in the margin next to the revised text. This lets the reader know that this passage is different now. (When text has been deleted, NFPA places a dot where the passage used to be.)

NFPA didn't indicate that this was a rule change in the 2002 edition, and did not add a line or insert a dot, but any mention of "five minutes" simply disappeared. Since they made no indication that this rule had been changed or omitted, I thought it might have been moved to another section of the book, but it wasn't. Therefore, programming the FACP to time out after five minutes is no longer a decision to be made by the AHJ. I marvel at how some rules that were OK for many years (even this option decided on a case-by-case basis) suddenly become illegal. The real question is: was allowing this 5-minute option a mistake all these years, or was the mistake made when it was omitted?

If your jurisdiction/state is referring to the 1993 through 1999 edition of NFPA 72 then auto-silencing might be an option. However, if your jurisdiction/state has adopted the newer 2002 edition of NFPA 72, then this is the new rule: "4.4.3.7 Alarm Signal Deactivation. A means for turning off activated alarm notification appliance(s) shall be permitted only if it complies with (A) through (D).

  1. The means shall be key-operated, located within a locked cabinet, or arranged to provide equivalent protection against unauthorized use.
  2. The means shall provide a visible zone alarm indication or the equivalent as specified in 4.4.6.1.
  3. (C) Subsequent actuation of initiating devices on other initiating device circuits or subsequent actuation of addressable initiating devices on signaling line circuits shall cause the notification appliances to reactivate.
  4. (D) A means that is left in the "off" position when there is no alarm shall operate an audible trouble signal until the means is restored to normal."

GREG KESSINGER, SET, CFPS, president of an alarm installing company since 1981, teaches NICET training classes to fire alarm system designers and installers and continuing education seminars for Ohio's fire alarm inspectors. You can reach him at 888-910-2272; e-mail: Greg@firealarm.org; or visit his website at www.FireAlarm.org.

author: By Greg Kessinger


Featured Local Company

OGBIO™

Biometric products and service center

267-475-7422
7827 Bradford St
Philadelphia, PA
http://www.ogbio.com

OGBIO is US-International based company which specializes in biometric products and services. We are committed to offer the honorable full service to the community by providing the innovation professional products and service with the best efforts and excellent outcome so that everyone enjoys the safest life and make the most convenient life.

OGBIO hopes to be memorized as the professional top brand of Biometric Security Products which change the world to the safest circumstances, and to be admired at our values, deeds and the every process in our lives as an exemplary ideal society. Each one of us is a precious individual, who deserves to be respected and encouraged. The company and all members protect and develop each other as a social family pursuing each other’s growth and happiness.

Related Local Events
TRACC Luncheon at Moravian Hall Square - Preparing for Your Future and Financial Security
Dates: 11/19/2009 - 11/19/2009
Location: Moravian Hall Square
Nazareth, PA
View Details

Public Safety Training Facility Grand Opening
Dates: 10/26/2009 - 11/1/2009
Location: Bensalem Township Country Club's Open House
Bensalem, PA
View Details

Member Lunch
Dates: 10/20/2009 - 10/20/2009
Location: Ruffini’s Restaurant
Thorndale, PA
View Details

Public Safety Training Facility Grand Opening
Dates: 10/19/2009 - 10/25/2009
Location: Bensalem Township Country Club's Open House
Bensalem, PA
View Details