Relays and Circuits for Life Safety Functions Philadelphia PA

Read more on Relays and Circuits for Life Safety Functions ...

Local Companies

OGBIO™
267-475-7422
7827 Bradford St
Philadelphia, PA
Main Line Fire & Security
(215) 464-9280
Philadelphia, PA
Nasir Da-Ood
(215) 276-2221
7344 N 21st St
Philadelphia, PA
Fortress Protection
(215) 854-8400
Philadelphia, PA
Fidelity Burglar & Fire Alarm Co Inc
(215) 673-8800
1900 Woodhaven Rd
Philadelphia, PA
Brunell & Sons Inc
(215) 624-5035
8701 Torresdale Ave Ste K
Philadelphia, PA
Honeywell
(215) 922-7450
313 Callowhill St
Philadelphia, PA
Honeywell
(215) 922-7450
313 Callowhill St
Philadelphia, PA
Polaris Brown Llc
(215) 753-1963
410 Wadsworth Ave
Philadelphia, PA
Hi-Tech Security
(215) 533-0552
1731 Orthodox St
Philadelphia, PA

provided by: 

Q: Where in National Fire Protection Association (NFPA), Quincy, Mass., National Fire Alarm Code 72 can I find the rules for how to properly shut down a night club's stage lights when the fire alarm system is tripped? Where do I place the relays for unlocking stairwell doors to allow re-entry during a fire emergency?

A: Where lights and sounds interfere with a fire alarm signal, they should be reduced or eliminated. Chapter 7 of NFPA 72 (2007 edition) contains requirements for how notification appliances must function. Rules for making something not function are found in the protected premises, Chapter 6. Section 6.16 holds the secrets for how Protected Premises Fire Safety Functions are interconnected to the fire system. Fire safety functions can be performed by trained staff, but NFPA 72 also states that fire safety functions "shall be permitted to be performed automatically." The decision to power down equipment is up to the owner/designer and other standards. For example, the "Safety Code for Elevators and Escalators" requires elevator controls' power to be disconnected prior to the activation of sprinklers in the elevator's hoistway or machine room. Section 6.16 does state, however, that the power for general lighting and operation of elevators must not be interfered with.

Should you and the owner decide that it is desirable to interconnect the closed-circuit television surveillance (CCTV) system using pre-set pan-tilt-zoom positioning and/or control doors using the access control system, then section 6.16.2.1 backs you up, stating: "fire safety control functions shall not preclude the combination of fire alarm services with other services requiring monitoring of operations." This is accomplished by requiring the fire alarm system to use a listed relay or addressable module "to initiate control of protected premises fire safety functions" to be "located within three feet of the controlled circuit or appliance." Off the shelf "ice cube" relays are not permitted.

Section 6.16.2.4 of NFPA 72 allows the use of a relay that operates on loss of power when the wiring between the panel and the remote relay isn't monitored for integrity. However, when the relay used isn't fail-safe, then the wiring between the panel and the relay must be monitored for integrity but only to the extent described in section 4.4.7 and the applicable provisions of Article 760 of the National Electrical Code.

These same rules also pertain to the relays and circuits controlling electrified locksets used on high-rise stairwell doors:

  • There is no requirement for the relay to be within three feet of each door when the relay is installed to properly control the electrical circuit powering these devices. — You must use the supplied wiring connections provided within the door hardware or provided with its "listed-for-the-purpose" power supply.
  • There is no code requirement to monitor the fire safety device's wiring beyond the fire alarm system's relay or after a digitally controlled network interface.
  • There is no limit to the distance between the fire alarm relay and the controlled device, as long as the relay is within three feet of the controlled circuit.
  • No other system is allowed to control the fire alarm system.

Greg Kessinger, SET, CFPS, president of an alarm installing company since 1981, teaches NICET training classes to fire alarm system designers and installers and continuing education seminars for Ohio's fire alarm inspectors. You can reach him at 888-910-2272; e-mail: Greg@firealarm.org; or visit his website at www.FireAlarm.org.

author: By Greg Kessinger


Featured Local Company

OGBIO™

Biometric products and service center

267-475-7422
7827 Bradford St
Philadelphia, PA
http://www.ogbio.com

OGBIO is US-International based company which specializes in biometric products and services. We are committed to offer the honorable full service to the community by providing the innovation professional products and service with the best efforts and excellent outcome so that everyone enjoys the safest life and make the most convenient life.

OGBIO hopes to be memorized as the professional top brand of Biometric Security Products which change the world to the safest circumstances, and to be admired at our values, deeds and the every process in our lives as an exemplary ideal society. Each one of us is a precious individual, who deserves to be respected and encouraged. The company and all members protect and develop each other as a social family pursuing each other’s growth and happiness.

Related Local Events
Public Safety Training Facility Grand Opening
Dates: 10/26/2009 - 11/1/2009
Location: Bensalem Township Country Club's Open House
Bensalem, PA
View Details

Member Lunch
Dates: 10/20/2009 - 10/20/2009
Location: Ruffini’s Restaurant
Thorndale, PA
View Details

Public Safety Training Facility Grand Opening
Dates: 10/19/2009 - 10/25/2009
Location: Bensalem Township Country Club's Open House
Bensalem, PA
View Details